Quality · Certificates
Certificates of analysis, verifiable with the laboratory
Every certificate is issued by an independent laboratory and can be checked on its portal with the access code. You don't have to take our word for it: just verify it.
- 3
- certificates published
- 99.10%
- lowest purity among published batches
- HPLC
- purity and identity
- ISO/IEC 17025
- laboratory accreditation
Certificate of analysis · COA-2026-8PSRP2
Tirzepatide 20 mg
PDF
99.90%Pass
Purity by HPLC · Batch TR-20MG-0814A · Analysed Oct 20, 2026
| Test | Result | Status |
|---|---|---|
| Peptide purity (HPLC)Specification ≥ 95.0% | 99.90% | Pass |
| Identity (retention time)Against a Tirzepatide standard | Confirmed | Pass |
| Net peptide contentLabelled: 20 mg · report only | 21.43 mg | Report only |
| Fentanyl screenImmunoassay, 50 ng/mL cutoff | Not detected | Pass |
- Laboratory
- ILS Laboratories (San Diego, CA, USA): independent, ISO/IEC 17025 accredited.
- Certificate no.
- COA-2026-8PSRP2
- Batch
- TR-20MG-0814A
- Sample received
- Oct 16, 2026
- Analysis
- Oct 20, 2026
Access code: D3XM9JKE

Certificate for the most recently analysed batch. Results refer to the sample the laboratory received; the laboratory does not assess or endorse manufacturing processes. The instrument reports a maximum of 99.9%. For research use only.
Certificate of analysis · COA-2026-SLSQCV
Tesamorelin 10 mg
PDF
99.48%Pass
Purity by HPLC · Batch TES-10MG-0924A · Analysed Oct 20, 2026
| Test | Result | Status |
|---|---|---|
| Peptide purity (HPLC)Specification ≥ 95.0% | 99.48% | Pass |
| Identity (retention time)Against a Tesamorelin standard | Confirmed | Pass |
| Net peptide contentLabelled: 10 mg · report only | 10.56 mg | Report only |
| Fentanyl screenImmunoassay, 50 ng/mL cutoff | Not detected | Pass |
- Laboratory
- ILS Laboratories (San Diego, CA, USA): independent, ISO/IEC 17025 accredited.
- Certificate no.
- COA-2026-SLSQCV
- Batch
- TES-10MG-0924A
- Sample received
- Oct 16, 2026
- Analysis
- Oct 20, 2026
Access code: BFEPE2TB

Certificate for the most recently analysed batch. Results refer to the sample the laboratory received; the laboratory does not assess or endorse manufacturing processes. For research use only.
Certificate of analysis · COA-2026-4ZE8GH
Retatrutide 20 mg
PDF
99.10%Pass
Purity by HPLC · Batch RT-20MG-0726A · Analysed Oct 20, 2026
| Test | Result | Status |
|---|---|---|
| Peptide purity (HPLC)Specification ≥ 95.0% | 99.10% | Pass |
| Identity (retention time)Against a Retatrutide standard | Confirmed | Pass |
| Net peptide contentLabelled: 20 mg · report only | 21.25 mg | Report only |
| Fentanyl screenImmunoassay, 50 ng/mL cutoff | Not detected | Pass |
- Laboratory
- ILS Laboratories (San Diego, CA, USA): independent, ISO/IEC 17025 accredited.
- Certificate no.
- COA-2026-4ZE8GH
- Batch
- RT-20MG-0726A
- Sample received
- Oct 16, 2026
- Analysis
- Oct 20, 2026
Access code: Z83UWLZ8

Certificate for the most recently analysed batch. Results refer to the sample the laboratory received; the laboratory does not assess or endorse manufacturing processes. For research use only.
How to verify a certificate
- Open the verificationClick “Verify with the laboratory”. It opens the ILS Laboratories portal, not a page of ours.
- Enter the codeIf the portal asks for it, enter the access code printed on the certificate.
- CompareThe portal shows the batch and the results the laboratory recorded. They must match the ones on this page.
What each test measures
- Purity by HPLC
- Liquid chromatography separates the compound from everything that accompanies it. Purity is the area of the main peak against all peptide peaks, measured at 214 nm.
- Identity
- The time the compound takes to leave the column is compared with a reference standard of the same compound. If it matches, it is the one on the label.
- Net content
- How many milligrams of peptide are in the vial. It is reported without a specification: a figure, not a pass/fail test.
- Fentanyl screen
- An immunoassay with a 50 ng/mL cutoff rules out fentanyl in the sample.
Certificates are published batch by batch, as the laboratory issues them.